- VistaPure™ (Built After 10/20/08)
- VistaPure™ (Built Prior to 10/20/08)
| Complete System Model Number | V3000 |
| Autoclave Wand Specification | Distilled-Quality ( 000-005 ppm ) |
| Bottle Faucet Specification | Ultra Pure-Quality ( 005-025 ppm ) |
| Maximum Operating Temperature | 100° F |
| Minimum Operating Temperature | 45° F |
| Maximum Operating Pressure | 100 psi |
| Minimum Operating Pressure | 40 psi |
| Optimal pH Range | 6.5 – 8.5 |
| Maximum Total Dissolved Solids (TDS) | 500 |
| Maximum pH Range | 5.5 – 9.5 |
| Maximum Influent Hardness | 10 gr/171 ppm |
| Maximum Influent Manganese | 0.05 ppm |
| Maximum Influent Iron | 0.1 ppm |
| Maximum Influent Hydrogen Sulfide | 0.00 |
| Maximum Influent Chlorine/Chloramine | 2 ppm |
| Maximum Daily Output (12 hours) | 25 gal (94 L) |
| Pre / Post Filter Element Service Life | 1 year max |
| Pre / Post Filter Replacement Order # (2 required) | R5633 ( Positions #1 & #5 ) |
| Deionization Element Service Life | 4-18 mo |
| Deionization Replacement Order # (2 required) | R5662 ( Positions #2 & #3 ) |
| Hyperfiltration Element Service Life | 3-5 years |
| Hyperfiltration Replacement Order # (1 required) | R3080 ( Position #4 ) |
| System Dimensions (W x H x D) | 22” x 16” x 5” |
| Tank Dimensions (Dia x H) | 11” x 16” |
| Approximate Shipping Weight | 36 lbs - (2 Cartons) |
| Complete System Model Number | V3000 |
| Autoclave Wand Specification | Distilled-Quality ( 000-005 ppm ) |
| Bottle Faucet Specification | Ultra Pure-Quality ( 002-015 ppm ) |
| Maximum Operating Temperature | 100° F |
| Minimum Operating Temperature | 45° F |
| Maximum Operating Pressure | 100 psi |
| Minimum Operating Pressure | 40 psi |
| Optimal pH Range | 6.5 – 8.5 |
| Maximum Total Dissolved Solids (TDS) | 500 |
| Maximum pH Range | 5.5 – 9.5 |
| Maximum Influent Hardness | 10 gr/171 ppm |
| Maximum Influent Manganese | 0.05 ppm |
| Maximum Influent Iron | 0.1 ppm |
| Maximum Influent Hydrogen Sulfide | 0.00 |
| Maximum Influent Chlorine/Chloramine | 2 ppm |
| Maximum Daily Output (12 hours) | 25 gal (94 L) |
| Prefilter Element Service Life | 1 year max |
| Prefilter Replacement Order # (1 required) | R5633 ( Position #1 ) |
| Deionization Element Service Life | 4-18 mo |
| Deionization Replacement Order # (2 required) | R5662 ( Positions #2 & #3 ) |
| Hyperfiltration Element Service Life | 3-5 years |
| Hyperfiltration Replacement Order # (1 required) | R3080 ( Position #4 ) |
| Polishing Filter Element Service Life | 1 year max |
| Polishing Filter Replacement Order # (1 required) | R2551 ( Position #5 ) |
| System Dimensions (W x H x D) | 22” x 16” x 5” |
| Tank Dimensions (Dia x H) | 11” x 16” |
| Approximate Shipping Weight | 33 lbs - (2 Cartons) |